一、概 述
隨著我國大中型(xing)(xing)企業(ye)(ye)逐年(nian)增(zeng)多,電(dian)(dian)(dian)力(li)(li)工(gong)(gong)業(ye)(ye)迅速發展,電(dian)(dian)(dian)工(gong)(gong)需求量(liang)不斷增(zeng)加,變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)值班(ban)電(dian)(dian)(dian)工(gong)(gong)緊缺(que);“變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)值班(ban)電(dian)(dian)(dian)工(gong)(gong)技能(neng)(neng)(neng)(neng)培訓(xun)(xun)考(kao)(kao)(kao)核(he)系統”就是(shi)為配(pei)(pei)(pei)合變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)值班(ban)電(dian)(dian)(dian)工(gong)(gong)考(kao)(kao)(kao)級,依據勞動和社會保障部《變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)值班(ban)電(dian)(dian)(dian)工(gong)(gong)職業(ye)(ye)標(biao)準》,參(can)考(kao)(kao)(kao)勞動和社會保障部、電(dian)(dian)(dian)力(li)(li)行業(ye)(ye)職業(ye)(ye)技能(neng)(neng)(neng)(neng)鑒定指導中心、機械工(gong)(gong)業(ye)(ye)職業(ye)(ye)技能(neng)(neng)(neng)(neng)鑒定指導中心、能(neng)(neng)(neng)(neng)源部電(dian)(dian)(dian)力(li)(li)司編(bian)寫的(de)相(xiang)關職業(ye)(ye)技能(neng)(neng)(neng)(neng)鑒定指導書、培訓(xun)(xun)大綱、培訓(xun)(xun)教材、題(ti)庫(ku)而(er)研制的(de)。本系統以(yi)35KV變(bian)電(dian)(dian)(dian)站為一(yi)次系統模型(xing)(xing),采用部分典型(xing)(xing)、常(chang)用一(yi)次真(zhen)實(shi)元(yuan)件(jian)與系統模擬控(kong)制屏相(xiang)結合的(de)形式,實(shi)訓(xun)(xun)項目涉及(ji)(ji)變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)的(de)高低壓(ya)電(dian)(dian)(dian)器(qi)與成套(tao)設(she)(she)備、監盤與抄(chao)表、電(dian)(dian)(dian)力(li)(li)繼(ji)電(dian)(dian)(dian)器(qi)及(ji)(ji)繼(ji)電(dian)(dian)(dian)保護、倒閘操作、典型(xing)(xing)低壓(ya)電(dian)(dian)(dian)氣線路(lu)等內容,可以(yi)作為職業(ye)(ye)學校、技工(gong)(gong)學校的(de)供配(pei)(pei)(pei)電(dian)(dian)(dian)專業(ye)(ye)及(ji)(ji)相(xiang)關專業(ye)(ye)學生實(shi)訓(xun)(xun)設(she)(she)備和變(bian)配(pei)(pei)(pei)電(dian)(dian)(dian)室(shi)(shi)(shi)(shi)值班(ban)電(dian)(dian)(dian)工(gong)(gong)培訓(xun)(xun)考(kao)(kao)(kao)核(he)鑒定平(ping)臺。
二、特 點
1.一次系統采用典型(xing)、現場常用的真(zhen)實元件,全力(li)創造專業崗位的真(zhen)實環境;
2.一次系統接線典型(xing)、豐富(fu),可以模擬(ni)實(shi)現各種(zhong)要求下的倒閘操作;
3.實訓(xun)項目齊全,能較(jiao)好地滿足培(pei)訓(xun)考(kao)核鑒定要求。
三、技術性(xing)能
1.輸(shu)入電源: 三相五(wu)線~380V±10% 50HZ
2.容量:<5kVA
3.工作環境:溫度-10℃~+40℃ 相對濕度<85%(25℃) 海撥<4000m
四(si)、實(shi)訓項(xiang)目
高、低壓開關(guan)與成套設備的認知(zhi)與操作
1.10kV高壓隔離開關(guan)的認知與操作
2.10kV高(gao)壓真空斷路器的認知與(yu)操作
3.10kV高壓開關柜的認知與操作
4.FC13型低壓刀(dao)開關的認知與操作
5.FC15型低壓(ya)萬能(neng)斷路器的認(ren)知與操作(zuo)
6.低壓塑殼斷路器(qi)的認知與操作(zuo)
7.0.4kV低(di)壓開關(guan)柜的認知與操作
高(gao)、低壓電(dian)流、電(dian)壓互感(gan)器的認知與接線
8.高、低壓電流(liu)互(hu)感器(qi)的認知(zhi)與接線
9.高、低壓電(dian)壓互感器的認知與接線(xian)
電力(li)繼電器結(jie)構認識與特性(xing)測試
10.電(dian)流繼電(dian)器的特性
11.電(dian)(dian)壓(ya)繼電(dian)(dian)器(qi)的特(te)性
12.中間繼電器(qi)的特性
13.時間繼電(dian)器的特(te)性
14.閃光繼電器的特性
15.反時限繼電器的特性(xing)
供(gong)配電系統繼電保護
16.供電線(xian)路帶時(shi)限過電流保護電路的接線(xian)與(yu)調試
17.供電線(xian)路低(di)電壓啟動過電流(liu)保護電路的(de)接線(xian)與調試(shi)
18.供(gong)電線路電流速(su)斷保護電路的接(jie)線與(yu)調試
19.供電線路電流(liu)反時限過電流(liu)保護電路的接線與調試(shi)
20.配(pei)電(dian)變(bian)壓器過(guo)電(dian)流保護電(dian)路的接線與調試
21.配電變(bian)壓器(qi)的(de)電流(liu)速斷(duan)保護電路的(de)接線與調試
22.配(pei)電變壓器的過負荷保護電路(lu)的接線與調試(shi)
23.變壓器的模擬超溫保護
供配電(dian)系統(tong)的二次回路與自(zi)動(dong)裝置
24.斷(duan)路器的(de)控(kong)制和信號回路
25.6~35KV系(xi)統的(de)絕緣監視裝置電路
26.供配電系(xi)統一次重合閘
27.線路過電流保護與自(zi)動重合閘綜合
28.功(gong)率因數補償(chang)
35kV變電站監盤與抄(chao)表
29.三相多功能(neng)智能(neng)儀表的(de)使用和參數設(she)置(zhi)
30.智能溫(wen)濕度控制(zhi)器的使用和(he)參數設置
31.系統運行(xing)狀態監視
32.35kV雙路進線(xian)電量監測
33.35kV變電(dian)站(zhan)主變電(dian)量監(jian)測
35kV變電站倒閘操作
34.系統運行(xing)方式(shi)切換倒閘操作
35.線路停電倒閘操作
36.線路送電倒閘操作
37.兩路進線供電轉一(yi)路供電倒閘操(cao)作
38.一(yi)路(lu)進線供電(dian)轉兩路(lu)供電(dian)倒閘操作
39.雙母運(yun)行狀態切換(huan)倒閘操作
40.分段單母運行狀態切換(huan)倒閘操作(zuo)
41.母線從運行(xing)狀態轉(zhuan)檢修倒閘操作
42.母線從檢修狀態轉運行倒閘操作
43.變壓器從運行狀(zhuang)態轉檢修倒閘(zha)操作
44.變壓器從檢修狀轉(zhuan)運(yun)行倒閘(zha)操作
45.變壓器從運行狀態(tai)轉(zhuan)冷(leng)備用(yong)倒閘操(cao)作
46.變壓器從運(yun)行狀態轉熱備用倒(dao)閘(zha)操作
47.變壓(ya)器(qi)從冷備用狀態轉運行(xing)倒閘操(cao)作
48.變壓器(qi)從熱備用狀(zhuang)態轉運行倒(dao)閘操作
49.出線開關(guan)從運行(xing)狀(zhuang)態轉檢修倒閘(zha)操(cao)作
50.出(chu)線從檢(jian)修狀態轉冷備用倒閘操作
51.出線(xian)從(cong)冷備用(yong)轉熱備用(yong)倒閘操作
52.出線從熱(re)備用轉運行(xing)倒(dao)閘操作(zuo)
53.出線從檢(jian)修轉運行倒閘操作
54.典型(xing)低壓(ya)電氣線(xian)路的接(jie)線(xian)與調試